The NIVOPOINT magnetic float level switch is used on liquids for switching level points (high and low) or for triggering alarms (emptying, filling).
The NIVOPOINT series is only recommended for non-viscous liquids that are not sticky and do not contain any magnetic particles or suspended solids.
DESCRIPTION
Switches located in the tube are activated by the magnetic float. As it passes, the contacts change state.
Installation and recommendation: If access to the tank is available, the float can be installed from the bottom of the NIVOPOINT controller (lower stop to be removed). If no other access is available, it is recommended to provide a 2" connection to allow the float to pass through.
Quick installation: The height of the contacts is determined prior to manufacturing in order to facilitate on-site installation and ensure the positioning of the contacts in relation to the installation plan.
TECHNICAL FEATURES
Measurement height
0.25 to 3 meters
Operating temperature
-40 °C...+150 °C (or depending on EX classification)
Operating pressure
25 bar at 20°C
Average density
min. 0,8 kg/dm³
Materials:
Stem and fitting
AISI 316 Ti (1.4571)
Float
AISI 316 L (1.4404)
Seal
Klingerit (for models with BSP connection)
Electrical contacts:
Number
1 to 5 reed contacts (NO or NC to be specified)
Breaking capacity
120 W / VA, 250 V AC, 3 A / 9 A max.
Switching differential
< 10 mm
Distance between 2 contacts
Minimum 110 mm
Electrical connection
M20x1.5 cable gland Cable diameter: Ø6…12 mm
Process fitting
1“ or 2” BSP/NPT
Electrical protection
Classe I
Ingress protection
IP 67 in accordance with EN 60529:2015
Weight
0,45 kg + 0,3 kg/m
Storage conditions
-20 °C..+ 60 °C
CE compliance: The device meets the legal requirements of the applicable European Directives.