| DB SERIE, Orifice Plate Flowmeter |
General Catalogue 765 |
|
DB SERIE, Orifice Plate Flowmeter
- Designed for agressive fluids - Direct reading indicator - From ND 50 up to ND 200 pipes - Scale amplification from 2 to 10. - Mounting in all positions - Standardized with NF X 10-102 Norm - Accuracy: ±2,5 % full scale - Option: Electrical switch counter |
Diaphragm is inserted between 2 flanges in the main duct. The differential pressure is transmitted to the exterior via 2 pressure ports on each diaphragm face. This pressure is proportional to the flow rate square in circulation inside of the duct. A flowmeter, mounting in derivation allow a direct reading of the flow rate. To obtain a strictly proportional to the main flow rate, a BORDA injector is insert before or after flowmeter. This flowmeter can be replaced by a counter, allowing a totalization. Orifices can be only delivered in stainless steel 316 L, or with pressure ports directly on steel or stainless steel. Their accuracy is 1%, diameters are from 50 and 60 mm. We supply flowmeter with special graduation for derivated measure on all existing diaphragm, only if specifications are given before graduation.
Measuring range : From 2 to 350 m3/h (see table on the back) Accuracy : ±3 % (DB/IDP) ±4 % (DB/PDP) Repeatability : ±0,3 % (DB/IDP) ±0,4 % (DB/PDP) Scale amplification : 2 to 10 (DB/IDP) 2,5 to 10 (DB/PDP)
Max. temperature : 50°C - PVC 90°- PPH 120°C - PVDF
Max. pressure : 10 bar (20°C)
Diaphragm : PVC - PPH - PVDF
Flowmeter associated : PVC (DB/IDP-V - DB/PDP-V) Trogamid (DB/IDP-T - DB/PDP-T) Polysulfon (DB/IDP-P - DB/PDP-P)
Float : PVDF Supply line : PVC - PPH - PVDF Stop valves : PVC - PPH - PVDF O-Ring : EPDM (standard) - FPM (on request) BORDA injector : PVC - PPH - PVDF
For DB/IDP : Electrical switch ZE 951 For DB/PDP : Electrical switch ZE 951
Ranges indicated on the attached board, for DB/PDP flowmeters , are not contractual, but can be modified within flow rate or diameter. For DB IDP, minima flow rates have to be multiplied by 1,25. Flow rates are indicated for PVC NP 10 pipes. In all events, the thickness and the exact interior diameter pipe have to be specified, so we may assure the specifications of the system
The loss of charge is the difference of pressure between upstream and dowmstream unrecoverable, create by the orifice. This loss of charge can be calculated on request.
 |
 |
 |
 |
INSTALLATION REQUIREMENTS |
 |
 |
 |
 |
The installation conditions are useful to warrant a coherent measure in the range of precision. The straight pipe lenghts upstream of the orifice, undermentioned, are given for indication.
Number of D 07 Simple elbow at 90°or T (flow rate by one branch) 17 2 elbows at 90°in 2 different plans 07 Reducing from 2 D to D on lenght 1,5 D to 3 D 07 Valve completly open (type membran valve or ball valve) 03 Downstream
The straight pipe lenght upstream depend to relation between intern pipe diameter (D), and the diameter orifice. The exact lenght to respect for conserving the precision of whole measure are communicated after each case study.
The union nuts will be center with the flange of fixation as precisely as possible. The union nut arrest boards should be of the same diameter than intern diameter of tube, to avoid perturbation in liquid flow. On resquest, we can deliver union nuts, flanges and screew.
|
 |
|
Orifice Plate Flowmeter
DB SERIE |
General Catalogue
765 |
|
|
|