Level detection probes to use with ES2001 control relay From 1 to 5 probes
APPLICATIONS
- HE version: Level detection on neutral liquids - HS version: Level detection on aggressives liquids
DESCRIPTION
Probes HE and HS, hanged electrodes, are to be in use with relays ES2001 for detection of liquid levels in storage tank. Depending on the model, up to 5 levels can be detected using the wall tank as a reference electrode; Provide a reference electrode if the tank is made of insulating material (i.e. up to 4 level detection + 1 reference). This technical solution is not suitable for liquids with hydrocarbons or grease or for any other application where an insulating layer is liable to deposit on the electrodes. They were developed for hanging in containers and shafts with lengths over 1000 mm.
TECHNICAL FEATURES
Fitting material
HE: PP HS: PVC
Cable
HE: Flexible PVC HS: Special cable coated with PES
Housing
PBT, glass fiber reinforced
HS probe body
PVC
Ambient temperature
-20 ... +60 °C
Liquid temperature
HE version: 0 ... +60 °C, HS version: Depends of chemical resistance of PVC and PES
Pressure
0.5 bar (Immersion depth Max. 5 m with SG = 1)
Protection
IP 65 according EN 60 529
Minimum for cable lengths L1 & L2:
HE: 0.3 m HS: 0.2 m
Maximum for cable lengths L1 ... L5:
25 m
EC Conformity: The instrument meets the legal requirements of the current European Directives.
General Catalog 542-01 13/09/2025 14:12
Resistive level with flexible probes HE - HS
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France