Continuous output version with magnetic transmission (cf datasheet 586-01)
APPLICATIONS
- Level detection on liquids compatible with stainless steel MNR 7-I is suitable for liquids, not viscous, not clogging and free of suspended solid particles.
DESCRIPTION
The Reed contacts inside the stem are actuated when the magnetic float passes in front of; Detection of up to 4 thresholds. The contacts are changeover and bistable: status reverses only when the float passes again in front of.
Tterminals are in an aluminum housing, IP 65 (cable gland M20 x1.5); Wiring diagram is shown on the board inside. A nut limits the float movement at the stem end: by unscrewing the nut, the float is easily removed.
Tip: The 2 "connection model with Ø 52 mm float and the DN 100 flange option, allow direct installation without removing the float.
TECHNICAL FEATURES
Stem height
Min. 250 mm / Max. 3,000 mm
Liquid density
Float Ø 91: Minimum 0.75 Float Ø 52: Minimum 0.85
Pressure limit
Max. 25 bar at 20 °C
Ambient temperature
-20 ... +70 °C
Operating temperature
-10 ... +100 °C
Reed contacts
Changeover and bistable
Switching power
40 VA / 220 V / 0.5 A
Shortest gap
100 mm between 2 contacts
Accuracy
±2 mm
Hysteresis
8 mm
Floats
Ø 52, height 88 mm; Density: Min. 0.85 Ø 91, height 110 mm; Density: Min. 0.75)
Connections
IP 68 enclosure (provided correct tightening of the cable gland), painted aluminum Cable gland M20 x1.5 (for cables Ø 5 ... 9 mm)
Fittings
2" BSP M threaded fitting (recommended) ½" BSP M threaded connection (Option: DN 100 flange)
Materials
Stem
AISI 316 L (DIN 1.4404)
Float
AISI 316 Ti (DIN 1.4571)
Fittings
AISI 316 Ti (DIN 1.4571)
Flange
AISI 316 L (DIN 1.4404)
EC Conformity: The instrument meets the legal requirements of the current European Directives.
General Catalog 550-02 07/10/2025 15:54
Magnetic level controllers in stainless steel MNR 7 - I
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France