Swimming pool and spa water treatment (freshwater or seawater)
DESCRIPTION
The CC1 closed-cell amperometric chlorine sensor detects and quantifies chlorine concentration in water. Equipped with three electrodes (measure, reference and auxiliary electrodes) immersed in an electrolyte, this probe ensures a controlled environment for the electrodes, optimizing measurement accuracy and stability.
Suitable for swimming pools : The CC1 probe is particularly suitable for swimming pools, as it tolerates up to 500 mg/l of isocyanuric acid, a stabilizer commonly used in pool water.
Installation recommendations : The need to maintain and control a constant flow rate of the water analyzed requires the use of an appropriate measuring cell (see datasheet 193-95). To simplify the installation of your control and measurement system, we propose to preinstall the components on a wall mounted panel.
Option for in-line measurement up to 3 bar : The probe is designed to operate at a maximum pressure of 0.5 bar. However, with the optional retaining ring, maximum pressure can be increased up to 3 bar. This option must be specified prior to manufacture, so that the probe can be properly fitted to the measuring chamber.
General Catalog 193-06 05/05/2025 10:31
Sensor for free chlorine with stabilizers CC1
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France