• All-plastic versions • Integrated transmitter and connection for test button • No moving parts • For aggressive and conductive liquids • NPN / PNP interface
Certificates
- General building supervisory approval issued by DIBt: Z-65.40-496 - Certification of Product Approval by SVTI ASIT: KVU-Nr. 321.012.19 - Vlarem II (Corcon bvba) certificate: CP0914/3073-HCC001
APPLICATION
Leakage sensor in accordance with the German Water Resources Act (WHG) for double-walled pipings to store, bottle and turn over water-polluting, electrically conductive, non-flammable liquids.
DESCRIPTION
The MAXIMAT LW CX SDR compact leakage sensor are designed to detect leaks in double-walled pipings with water-polluting liquids. When an electrically conductive liquid comes into contact with the detection sensor, the integrated electronics respond by interrupting the continuous output signal. This signal can be read out from the system controller as acoustic and optical alarm.
General Catalog 556-04 22/10/2021 09:24
On-line leak detector in double-walled piping MAXIMAT® LW CX SDR
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France