Recherche
MENU Catalog Global Sites
BAMO
INTERNATIONAL
European manufacturer of sensors and instruments for liquids
You are in BAMO EU » General Catalog » Turbidity » TURBISENS 2
General Catalog 443-02
TURBISENS 2
TURBISENS 2
Compact turbidimeter for immersion measurement
TURBISENS 2

BAMOWIZ displayer (Optional)

  • Compact transmitter with 4...20mA output
  • PVC or PP plastic version with sapphire glass windows
  • Measurement to DIN EN ISO 7027
  • Adjustable ranges up to 2000 FTU
  • Units: NTU / FNU / FAU / g/l SiO₂
APPLICATION

Control and monitoring of :
- Wastewater treatment plant outlets
- Sedimentation and settling processes
- Water tanks
- Cooling water basin

DESCRIPTION

The TURBISENS probe is used to measure the turbidity of a liquid.
It is designed for measurement in immersion, in tanks or open channels.

Turbidity expresses the clarity or transparency of a liquid, such as water, based on the presence of suspended particles that scatter and absorb light. The more turbid a liquid is, the less transparent it becomes.
The measuring principle is based on a combined transmitted light / scattered light measurement according to DIN EN ISO 7027,
One receiver is facing the transmitter at 180° for transmitted light measurement. A second receiver is positionned at an angle of 90° for scattered light measurement.
Transmitted light measurement is used for high turbidity values, it is usually referred to with the unit FAU.
Scattered light measurement is used for low turbidity values, it is usually referred to with the unit FNU or NTU.
Pure absorption measurement, expressed in FAU, or a pure scattered-light measurement, expressed in FNU.
Low turbidity can only be measured accurately using scattered light, while high turbidity requires transmitted light; therefore, not all measurement ranges are available for every unit.

A measuring range 0-100g/l SiO2 solids concentration can be selected, which works only by means of transmitted light measurement.

TECHNICAL DATA
Output signal   4...20mA calibrated on selected turbidity range, for use
with our BAMOWIZ or an analog PLC input
Supply voltage   10...30V DC, galvanically isolated from the measuring
circuit
Power consumption   < 1 W
     
Note: if the 4...20 mA measurement signal is supplied by the connected measuring
amplifier, the power consumption increases by 0.48 W (24 V DC × 20 mA).
     
Probe immersion depth   max. 10m
Protection rating   IP68 (max. 10 m / 1 bar) according to EN 60 529
Probe material   PVC / PP
Media temperature   0°C...60°C (PVC) or 0°...+80°C (PP)
Cable   TPK, length 6m (standard, special lengths on request),
resistant to diluted acids and alkalis
Cable output   Cable gland IP67 (the upper part of the probe is not
intended to be immersed permanently)
Sensor glasses   Sapphire glass
General Catalog 443-02
13/08/2026 18:24
Compact turbidimeter for immersion measurement
TURBISENS 2
Technical & Commercial support's main contacts
Ask a QUOTATION online
BAMO Mesures SAS
22, Rue de la Voie des Bans
Parc d'activités de la Gare
95100 ARGENTEUIL France
Tel : +33 (0)1 30 25 83 21
Fax : +33 (0)1 34 10 16 05
Email : export@bamo.fr
Site : http://www.bamo.eu
Siret : 314 055 864 000 65
TVA Intra : FR 08 314 055 864
APE : 4669 B
Capital : 400 000 €
Designed and hosted by CARIMEDIA since 1998
© 1998-2026 All rights reserved - Disclaimer