PVC or PP plastic version with sapphire glass windows
Measurement to DIN EN ISO 7027
Adjustable ranges up to 2000 FTU
Units: NTU / FNU / FAU / g/l SiO₂
APPLICATION
Control and monitoring of : - Wastewater treatment plant outlets - Sedimentation and settling processes - Water tanks - Cooling water basin
DESCRIPTION
The TURBISENS probe is used to measure the turbidity of a liquid. It is designed for measurement in immersion, in tanks or open channels.
Turbidity expresses the clarity or transparency of a liquid, such as water, based on the presence of suspended particles that scatter and absorb light. The more turbid a liquid is, the less transparent it becomes. The measuring principle is based on a combined transmitted light / scattered light measurement according to DIN EN ISO 7027, One receiver is facing the transmitter at 180° for transmitted light measurement. A second receiver is positionned at an angle of 90° for scattered light measurement. Transmitted light measurement is used for high turbidity values, it is usually referred to with the unit FAU. Scattered light measurement is used for low turbidity values, it is usually referred to with the unit FNU or NTU. Pure absorption measurement, expressed in FAU, or a pure scattered-light measurement, expressed in FNU. Low turbidity can only be measured accurately using scattered light, while high turbidity requires transmitted light; therefore, not all measurement ranges are available for every unit.
A measuring range 0-100g/l SiO2 solids concentration can be selected, which works only by means of transmitted light measurement.
TECHNICAL DATA
Output signal
4...20mA calibrated on selected turbidity range, for use with our BAMOWIZ or an analog PLC input
Supply voltage
10...30V DC, galvanically isolated from the measuring circuit
Power consumption
< 1 W
Note: if the 4...20 mA measurement signal is supplied by the connected measuring amplifier, the power consumption increases by 0.48 W (24 V DC × 20 mA).
Probe immersion depth
max. 10m
Protection rating
IP68 (max. 10 m / 1 bar) according to EN 60 529
Probe material
PVC / PP
Media temperature
0°C...60°C (PVC) or 0°...+80°C (PP)
Cable
TPK, length 6m (standard, special lengths on request), resistant to diluted acids and alkalis
Cable output
Cable gland IP67 (the upper part of the probe is not intended to be immersed permanently)
Sensor glasses
Sapphire glass