| Preview | There are 100 results for | Relevancy |
![]() |
GsM 24e Modem GSM / GPRS Starting Up Notice (248-01)
Created on 28/10/2010 16:25 and updated on 10/04/2018 09:27 |
248-01![]() Starting Up Notice |
![]() |
NIVOSTOP ACS - English - Deutsch - Castellano Level controller, drinkable water agreement Starting Up Notice (523-01)
Created on 07/07/2011 14:39 and updated on 10/04/2018 09:49 |
523-01![]() Starting Up Notice |
![]() |
VE2V S4-PVC Electrically actuated 2-way ball valves Starting Up Notice (914-01)
Created on 05/01/2012 17:41 and updated on 10/04/2018 11:19 |
914-01![]() Starting Up Notice |
![]() |
9337 pH and ORP immersion probe – Built-in temperature sensor Page (130-02)
Electrode holder and protector Built-in temperature sensor Pt100 Easy calibration routine Adjustable flange or PE collar fitting For any electrode PG 13.5 PVC construction Cables: through 2 pressure glands Created on 19/10/2012 13:44 and updated on 15/04/2025 18:13 |
130-02![]() Page |
![]() |
U6 series ORIFICE PLATE FLOW INDICATOR Page (764-01)
Mounting in all positions Construction: cast iron or stainless steel For pipes from ND 40 up to ND 300 mm Scale amplification from 2 to 10 Accuracy: ± 2.5 % Options: High or/and Low flow switches Created on 16/06/2015 18:15 and updated on 10/04/2018 08:45 |
764-01![]() Page |
![]() |
BAMOPHAR 436 Starting Up Notice (436-02)
Created on 06/10/2017 09:45 and updated on 17/06/2021 09:38 |
436-02![]() Starting Up Notice |
|
BAMOSONIC Ultrasonic level transmitter (2-wire) Starting Up Notice (597-06)
Created on 23/07/2018 13:42 and updated on 13/12/2021 17:33 |
597-06![]() Starting Up Notice |
![]() |
VISIOFLUX WR Flow indicator Page (719-01)
• Visualization of flow with a rotor • Mounting in all positions • Up to 16 bar; Up to 100 °C • Cleaning without dismounting • For liquids • Fittings: BSP-F ¼'' ... 1 ½'' • Brass version or stainless steel Created on 19/11/2019 15:19 and updated on 14/01/2022 10:15 |
719-01![]() Page |
![]() |
HygroWiz Relative Humidity and Temperature Page (671-01)
• Local or remote display • Analogue output(s) 4-20 mA • Relay output(s) • Interface RS485 with MODBUS RTU Created on 17/03/2020 13:47 and updated on 30/06/2020 09:47 |
671-01![]() Page |
![]() |
FTL S4 In-line filter unit Page (955-02)
• Radial mounting and dismounting • Transparent body • Optimal passage features • Strainer: 1.8 x 3.4 mm Created on 18/10/2021 14:35 and updated on 17/04/2026 11:56 |
955-02![]() Page |
![]() |
Série P501 Pressure gauges, AISI, Ø 100, with magnetic contacts Page (812-69)
• Deep polycarbonate cover • Safe operating concept • 1 or 2 contacts in gauge Ø 100 Created on 23/06/2022 17:01 and updated on 23/06/2022 17:09 |
812-69![]() Page |
![]() |
BAMOPHOP 113 pH meter Page (113-02)
• Measurement 2...12 / 0...14 pH • Output 4-20 mA / 0-5 V / 0-10 V • 24 Vdc power supply • DIN rail mounting Created on 15/04/2025 15:53 and updated on 15/04/2025 18:38 |
113-02![]() Page |
|
BAMOFLO MAG 774 Electromagnetic flowmeter Starting Up Notice (774-01)
Created on 24/09/2025 10:38 and updated on 20/05/2026 14:11 |
774-01![]() Starting Up Notice |
![]() |
9336 pH and ORP Immersion probes Page (130-01)
Electrode holder and protection Easy calibration: buffer flask grips on Flange or PE collar fitting For any KCl gel type electrodes For PG 13.5 electrode threaded connection PVC, PPH or stainless steel construction Wire outlet through a PG 9 Electrode... Created on 09/10/2006 00:07 and updated on 15/04/2025 18:13 |
130-01![]() Page |
![]() |
BSM 501 & BSM 515 English - Deutsch - Castellano Level switch Starting Up Notice (585-01)
Created on 11/10/2006 17:46 and updated on 10/04/2018 10:16 |
585-01![]() Starting Up Notice |
![]() |
9400 On-line holder for 1 pH or ORP electrode Starting Up Notice (141-01)
Created on 15/06/2007 17:26 and updated on 02/12/2021 09:24 |
141-01![]() Starting Up Notice |
![]() |
TWS Thermowells, welded body Page (635-01)
Body: welded tube AISI 316 L, PVC, PPH, PVDF Fittings: Threads: BSP or NPT ½'' ; NPT ¾'' Flanges: DN 32, 40 or 50 Created on 20/12/2007 14:35 and updated on 23/06/2025 17:35 |
635-01![]() Page |
![]() |
LISA Liquid Intrusion Safe Alarming System Starting Up Notice (544-03)
Created on 10/04/2009 18:31 and updated on 02/12/2021 10:47 |
544-03![]() Starting Up Notice |
![]() |
IFAT 2010 New Perspectives for the Environment News ()
We shall exhibit in Munich our products in IFAT 2010, the world's leading trade fair for water, sewage, waste and raw materials management. September 13-17, 2010 - New Munich trade fair centre. Created on 26/04/2010 11:43 and updated on 10/04/2018 11:27 |
![]() News |
![]() |
MW-10 – MW-11 Pocket photometers for chlorine measurement Page (190-11)
• For swimming pools or drinkable water • Measuring ranges: Free chlorine: 0.05 to 2.5 ppm (MW-10) Total chlorine: 0.05 to 2.5 ppm (MW-11) • Delivered ready to use Created on 15/12/2010 08:46 and updated on 06/01/2020 14:52 |
190-11![]() Page |
![]() |
VP2V S4-PVDF Pneumatically actuated 2-way ball valves, single / double acting Page (913-07)
NEW SERIES Please, see the folder 913-21 Created on 08/12/2011 14:15 and updated on 24/01/2022 17:28 |
913-07![]() Page |
![]() |
VEP K4-PVDF Electrically actuated butterfly valves Starting Up Notice (914-09)
Created on 28/03/2012 17:07 and updated on 10/04/2018 11:23 |
914-09![]() Starting Up Notice |
![]() |
MUDSENS Sludge level probe Page (599-02)
• Ultrasonic probe • Level monitoring of sludge in sedimentation tanks • Advanced algorithm • Output 4-20 mA: representative of sludge level • Cleaning with compressed air • User-friendly menu Created on 25/04/2013 16:50 and updated on 26/03/2022 19:28 |
599-02![]() Page |
![]() |
DKM Flow controller - Viscosity <600 Cst - 250/300 bar - 120 (160)°C - all positions - 0,5...90 l/min Page (723-01)
Metallic flow controller Created on 21/11/2014 11:48 and updated on 26/06/2023 17:55 |
723-01![]() Page |
![]() |
MAXIMAT LW CX Compact leak detector Page (556-07)
• All-plastic versions • Integrated transmitter and connection for test button • No moving parts • For retention on storage tanks • NPN / PNP interfaces Created on 12/02/2016 14:10 and updated on 07/11/2023 11:56 |
556-07![]() Page |
![]() |
GAD 531 Level detection for grease-water separators Page (531-05)
• Compact and economical model • Monitoring of grease-water separators • Relay output; Changeover contact • Audible and lighting LED alarms • Cable break and short circuit monitoring Created on 31/05/2018 17:38 and updated on 22/04/2022 14:11 |
531-05![]() Page |
![]() |
INTERNIV 590 Electronic gauge for diesel Page (590-06)
For storage tanks of diesel (fuel oils) Measuring ranges: Up to 3 m Output signal: 4-20 mA, power 8 ... 32 V DC Compact, robust probe (stainless steel) PVC cable compatible with diesel Created on 09/04/2019 17:33 and updated on 07/11/2025 10:54 |
590-06![]() Page |
![]() |
SIG 4.0 Analogue transmitter for flow controllers Page (720-10)
• For flow controllers • Output: 4 ... 20 mA or 0 ... 10 V • Accuracy: ±10 % FS • Already set in factory Created on 29/11/2019 15:03 and updated on 29/11/2019 15:09 |
720-10![]() Page |
![]() |
TYPE 620 Composite water-meter Page (786-02)
• Water-meter ND 15 or ND 20 • Composite body, dry dial head • Suitable with drinking water • High accuracy and repeatability • High resistance to aggressive, waste water Created on 08/06/2020 17:04 and updated on 09/10/2023 12:28 |
786-02![]() Page |
![]() |
VMP K4 Manual butterfly valves, chemistry series Page (945-04)
• Secure and padlockable handle • 10 adjustment positions • Wafer mounting, between flanges: DIN, ANSI, JIS Created on 15/02/2021 17:18 and updated on 17/04/2026 11:46 |
945-04![]() Page |
![]() |
D202 Gauge guard with ANSI flange Page (812-38)
• Large pressure range • Laser welded diaphragm • Range -1 ... 0 ... 400 bar • Flange ANSI B16.5 Created on 04/02/2022 16:37 and updated on 04/02/2022 16:49 |
812-38![]() Page |
|
INTERNIV 590 Electronic gauge for level of diesel Starting Up Notice (590-06)
Created on 25/02/2022 14:17 and updated on 25/02/2022 14:18 |
590-06![]() Starting Up Notice |
|
OZ10 Ozone sensor Starting Up Notice (193-22)
Created on 05/10/2023 09:55 and updated on 05/10/2023 09:56 |
193-22![]() Starting Up Notice |
![]() |
R-500 / R-600 Vibrating rod level switch Page (507-02)
For powders and granules Self-cleaning Programmable relay output ATEX version II 1/2 D ta/tb IIIC T90°C...T170°C Da/Db Created on 17/06/2025 13:09 and updated on 17/06/2025 13:12 |
507-02![]() Page |
General Catalog Category ()
Created on 23/09/2006 18:41 and updated on 03/04/2018 09:31 |
![]() Category |
![]() |
DEBIX serie Flow rate measuring probes Page (760-01)
Suitable for pipes from ND 15 to 3000 mm Low pressure drop Designed for liquids and gases Reliable, accuracy ± 1% Excellent repeatability Fast and economical installation Created on 09/10/2006 16:36 and updated on 26/03/2022 18:27 |
760-01![]() Page |
![]() |
TRUBOMAT GS3 Turbidity controller Starting Up Notice (410-01)
Created on 30/07/2007 16:51 and updated on 10/04/2018 09:35 |
410-01![]() Starting Up Notice |
![]() |
MAXIMAT SHRC Measuring transducer Starting Up Notice (555-06)
Created on 10/09/2008 16:01 and updated on 10/04/2018 10:04 |
555-06![]() Starting Up Notice |
![]() |
9346 pH - ORP Immersion probe Starting Up Notice (135-01)
Created on 04/12/2009 14:11 and updated on 10/04/2018 09:18 |
135-01![]() Starting Up Notice |
![]() |
CC1 Sensor for free chlorine with stabilizers Page (193-06)
Closed cell with diaphragm, 3 electrodes For swimming pool water monitoring Water sample may not content surface-active additives. Range: 0.01 to 10 ppm Output signal: 4-20 mA Pressure limit: 0.5 bar Temperature limit: 1...45 °C For swimming pools... Created on 27/09/2010 16:53 and updated on 05/05/2025 10:31 |
193-06![]() Page |
![]() |
ITU 404 - ITU 414 Panel mounting indicators Page (222-04)
• Versatile display indicator, programmable • Inputs: mA, V, Pt 100, Ni 100, TC, Potentiometric input • Power supply: 21.6 to 253 V AC 50/60 Hz and 19.2 to 300 V DC • 4 digits display / LED 14 segments • Power supply to sensor: 15 to 25 V DC /... Created on 19/01/2011 13:42 and updated on 06/07/2018 15:28 |
222-04![]() Page |
![]() |
VPP K4-PVC Pneumatically actuated butterfly valves, single / double acting Starting Up Notice (913-03)
Created on 12/12/2011 17:27 and updated on 10/04/2018 11:13 |
913-03![]() Starting Up Notice |
![]() |
EL Limnimetric scales Page (581-01)
- Metallic rulers for level indication in basins, rivers, harbours - Mounting: vertical, or 45° angle - Easy reading on large scale - Resistant to corrosion, climate strengths and seawater Created on 01/08/2014 16:57 and updated on 19/02/2020 17:28 |
581-01![]() Page |
![]() |
EVEREST 214S 2 Channels, 4 thresholds, Relay Page (232-04)
• 4 adjustable thresholds, one is available as a timer • Adjustable hysteresis • 24 V DC power supply to 2 sensors • 2 Inputs 4-20 mA • Built-in timer: 1 s up to 24 h, e.g. for venting operation on MEMPRO Created on 31/03/2015 17:42 and updated on 11/02/2022 13:09 |
232-04![]() Page |
![]() |
BAMOPHAR 451 Dissolved oxygen monitor Page (451-03)
• Dissolved oxygen measurement • Scales: 0.01 to 50 mg/l or 0 to 500 % • 1 Input for AQUAPLUS probe • 2 Analogue outputs 0/4-20mA • 4 Relay outputs (Thresholds and alarm) • OPTION: Extension terminal for 2nd measuring parameter Created on 11/05/2017 18:08 and updated on 16/06/2025 14:10 |
451-03![]() Page |
![]() |
BR1 Bromine sensor Page (193-09)
• For water treatment • Low incidence of pH changes • Surfactants: partial tolerance • Temperature: 45 °C max. • Pressure: 0.5 bar max. Created on 29/06/2018 15:39 and updated on 18/04/2025 04:46 |
193-09![]() Page |
![]() |
MAXIMAT TC1-B 1 Channel alarm unit Page (555-11)
• Alarm unit, for 1 dry-contact detector • Optical and acoustic alarms • Alarming until acknowledgement • Output relay : Changeover contact • Robust and inexpensive Created on 10/10/2019 16:55 and updated on 10/10/2019 16:59 |
555-11![]() Page |
![]() |
CAPSYTRON TLS Dry run protection Page (556-95)
• Wet parts in plastic materials • Compact probe • Plug for function test • Switches when pipe is empty • No moving parts Created on 17/12/2019 11:29 and updated on 10/03/2020 13:14 |
556-95![]() Page |
![]() |
E Series Variable area glass flow indicators Page (795-01)
• Direct reading • Accuracy ± 2 % • For liquids or for gases • Materials according ranges • Adjustable contacts Created on 30/06/2020 09:49 and updated on 30/06/2020 09:53 |
795-01![]() Page |
![]() |
OV 16 Oval wheel flow sensor Page (782-02)
• For viscous liquids: 5 to 8,000 cSt • Low pressure drop • Accuracy ±1 % • BSP-F ¼'' • Up to 10 bar Created on 19/03/2021 16:45 and updated on 18/07/2023 10:30 |
782-02![]() Page |
![]() |
PKK Multitask relay Page (251-02)
• Galvanic isolation • input 4-20 mA or potential free contact • Intrinsic safety • Settings on relay outputs • Power supply to sensor Created on 26/03/2022 19:23 and updated on 26/03/2022 19:25 |
251-02![]() Page |
![]() |
QATAR PROTECH TECHNICAL TRADING LLC ()
Mr 20241216141520 M Ezdan Building -7, Office# 6, ‘C’ Ring Road Doha-Qatar +97433759997 +97444691407 sales@ptt-inst.com Created on 16/12/2024 14:16 and updated on 16/12/2024 14:16 |
![]() |
![]() |
TURBINUM 442 Digital Turbidity Sensor Page (442-02)
Optical fiber IR measurement From 5 to 4000 NTU/FNU or 0 to 4500 mg/L 90° measurement using infrared at 850 nm Modbus RS-485 digital output In accordance with standard 7067 Created on 17/07/2025 16:46 and updated on 18/09/2025 10:35 |
442-02![]() Page |
![]() |
TVI & MINITEV Resistive level probes Page (541-01)
1 up to 4 electrodes Metal - PTFE Process connection: Gas or NPT Head housing: Cast aluminium • For all electrically conductive liquids • 1 to 4 electrodes • Materials: Metals - PTFE • Pressure up to 200 bar • Temperature up to 220 °C •... Created on 10/10/2006 16:34 and updated on 08/06/2020 16:15 |
541-01![]() Page |
![]() |
BAMOFLU 100 PADDLE WHEEL FLOW SENSOR Starting Up Notice (780-01)
Created on 28/05/2007 14:40 and updated on 06/12/2021 16:38 |
780-01![]() Starting Up Notice |
![]() |
RTM Continuous level transmitter Starting Up Notice (586-01)
Created on 14/09/2007 10:11 and updated on 25/03/2022 15:51 |
586-01![]() Starting Up Notice |
![]() |
CONDUCTIVITY Typical measuring ranges Page (300-99)
Created on 22/12/2008 14:53 and updated on 09/04/2018 17:37 |
300-99![]() Page |
![]() |
TURBISENS – TRUBOMAT – TURBICUBE Measuring and control of turbidity News ()
We clarify the parameters of fluids turbidity... Since 2 decades, we develop the range of turbidity monitors for continuous survey or just alarming systems. Wastewater: From WWTP, sedimentation process, flocculation... Drinkable water: From spring,... Created on 22/12/2009 14:23 and updated on 10/04/2018 11:34 |
![]() News |
![]() |
ITU Panel mounting indicator - 2 relays Starting Up Notice (222-03)
Created on 28/10/2010 17:34 and updated on 10/04/2018 09:25 |
222-03![]() Starting Up Notice |
![]() |
VE2V S4-PVC Electrically actuated 2-way PVC ball valves Page (914-01)
ND 10 to ND 100 In-line pattern Electric actuator, Position index Manual operating for immediate action NEW SERIES Please, see the folder 914-21 Created on 14/09/2011 09:16 and updated on 24/01/2022 17:31 |
914-01![]() Page |
![]() |
VM2V S4 Manually operated 2-way ball valves Page (934-02)
Secured handle, lockable In-line pattern 100% free way Secured handle, lockable In-line pattern 100% free way Created on 12/01/2012 18:00 and updated on 03/12/2025 17:25 |
934-02![]() Page |
![]() |
IDP Plastic flow indicator Page (730-05)
• Direct reading • All wet parts in plastics • Measuring tubes: PVC or Polysulfone • Ranges: Up to 60 m³/h Specific scales for Air, HCl, NaOH, etc. Options: Adjustable contacts 4-20 mA transmitter Created on 21/11/2012 14:20 and updated on 21/03/2022 16:37 |
730-05![]() Page |
![]() |
VP2V - INOX 2-way pneumatic valves, single or double acting Page (1013-01)
Stainless steel valve body Fittings from ¼'' up to 2'' Pneumatic actuator Single or double acting Position pointer OPTIONS: Limit switches box Pilot solenoid valves Created on 01/10/2014 17:37 and updated on 14/04/2026 15:04 |
1013-01![]() Page |
![]() |
MAGTOP D Level indicator - ATEX or/ and P.E.D. Page (560-03)
• Versions ATEX or and PED • Direct reading on two-color magnetic ruler • Temperature up to 450 °C • Pressure up to 250 bar • Options: Level switches, graduated ruler, Analogue signal transmitter Created on 04/09/2015 11:53 and updated on 14/03/2022 17:38 |
560-03![]() Page |
![]() |
GNR 6 LEVEL INDICATOR Page (572-01)
• Direct reading on site • Measuring tube O.D. 63 mm • Wet parts: PVC and PPH • Stop valves, included • Options: Level switches, graduated ruler Created on 12/12/2017 18:17 and updated on 08/10/2019 12:18 |
572-01![]() Page |
![]() |
GNR 5 / INOX Level indicator - Controller Page (575-01)
• Direct reading • Wet parts: AISI 316 L, glass, FPM • C to C: Up to 2000 mm Created on 10/08/2018 12:36 and updated on 14/03/2020 12:35 |
575-01![]() Page |
![]() |
VP2V M1 2-Way Pneumatic Valve – Single or Double Acting Page (913-21)
PVC-U / PP-H / PVDF valve from DN 10 to DN 100 Pneumatic actuator Single or double acting Options : Limit switch box Solenoid valve Created on 19/11/2019 17:03 and updated on 17/04/2026 11:42 |
913-21![]() Page |
![]() |
XMLA Pressure switches Page (892-03)
• Range: 0.4 ... 35 bar • Resistant to vibrations and shocks Created on 17/03/2020 14:44 and updated on 07/02/2022 11:56 |
892-03![]() Page |
![]() |
SGL In-line sight glass Page (719-10)
• Direct visualization of flows • ND 50 to ND 250 • Borosilicate glass tube • Pressure drop free • Simple - Reliable - Maintenance free Created on 30/12/2020 08:49 and updated on 30/12/2020 08:53 |
719-10![]() Page |
![]() |
MAGTOP G5 / G5C MAGNETIC FLAP INDICATOR Page (560-05)
• Bypass magnetic flap indicator • Options: with limit switches and/or 4-20 mA transmitter • Easy to handle Created on 22/10/2021 09:27 and updated on 22/10/2021 11:23 |
560-05![]() Page |
![]() |
BAMOBIF 282 Flow-rate indicator, plus totalizer Page (282-03)
• For flow sensors • Input: NPN, PNP, Push Pull • Frequency ranges: from 10 Hz up to 10 kHz • Power supply: 85 … 260 V AC • Display: 6 digits • 2 relay outputs, N.O. • 1 analogue output, 4-20mA Created on 27/06/2022 17:56 and updated on 04/07/2022 11:32 |
282-03![]() Page |
![]() |
pH meters Category ()
General Catalog/pH and ORP/ Created on 15/04/2025 16:11 and updated on 15/04/2025 18:26 |
![]() Category |
![]() |
TP 805-10 All stainless steel pressure transmitter Page (805-10)
Compact and robust design 4-20 mA output, 2 wires Relative pressure 0..2.5 to 0..16 bar Stainless steel fitting ½"G Option : ATEX, SIL 1, Marine Created on 07/11/2025 15:18 and updated on 07/11/2025 15:20 |
805-10![]() Page |
![]() |
9346 Immersion probe for pH and ORP measurements Page (135-01)
Electrodes holder and protection 2 or 3 electrodes, thread PG 13.5 PVC or PPH construction Flange or PE collar fitting Wire outlet through a cable gland Easy mounting on site • Electrode holder and protector • Easy calibration routine •... Created on 09/10/2006 00:16 and updated on 15/04/2025 18:14 |
135-01![]() Page |
![]() |
FS4 Top mounting level indicator Starting Up Notice (584-01)
Created on 11/10/2006 17:50 and updated on 25/03/2022 15:46 |
584-01![]() Starting Up Notice |
![]() |
TURBICUBE In-line turbidity measurement system Starting Up Notice (444-01)
Created on 20/06/2007 14:19 and updated on 16/07/2025 19:09 |
444-01![]() Starting Up Notice |
![]() |
MEMPRO Hydrostatic level transmitter Starting Up Notice (592-01)
Created on 26/12/2007 15:30 and updated on 10/04/2018 10:19 |
592-01![]() Starting Up Notice |
![]() |
NIVOIL Alarm system for oil-water separators Starting Up Notice (531-01)
Created on 21/04/2009 14:11 and updated on 10/04/2018 09:50 |
531-01![]() Starting Up Notice |
![]() |
ROMANIA Draft Industries Technology srl ()
Mr M Calea Rahovei 266-268 corp C63.03-02a 50912 Bucuresti +40 214 560 099 +40 214 561 199 sales@draftind.ro Created on 28/04/2010 13:28 and updated on 28/11/2011 14:55 |
![]() |
![]() |
DOSAControl DCW 100 Monitor for CCK sensors Page (194-05)
AUTO-CLEANING SENSOR by reverse polarity LCD back lighted display, friendly using menu 1 specific input for CCK sensor 1 analog output 0/4-20 mA Automatic temperature compensation 2 relays for ON/OFF and PID regulation Pulse output for ON-OFF, PID... Created on 15/12/2010 11:51 and updated on 26/02/2021 15:00 |
194-05![]() Page |
![]() |
VP3V S4-PVDF 3-Way Pneumatic Valve – Single or Double Acting Page (913-08)
PVDF valve from DN 10 to DN 50 Pneumatic actuator Single or double acting Visual position indicator Options: Limit switch box Created on 08/12/2011 14:24 and updated on 17/04/2026 11:41 |
913-08![]() Page |
|
NIVOSTOP PR2 Ex ATEX Float level switch Starting Up Notice (521-03)
Created on 03/07/2013 17:08 and updated on 07/02/2022 11:51 |
521-03![]() Starting Up Notice |
![]() |
VENTURI CHANNELS DEBITFLO Open channels with exponential section Page (755-30)
• 7 channels in composite material, with approach channels • Flow rates from 0.22 up to 1440 m³/h • Easy civil engineering Created on 21/11/2014 15:52 and updated on 08/06/2020 16:45 |
755-30![]() Page |
![]() |
IFAT 2016 News ()
We shall exhibit our products in IFAT 2016, the world's leading trade fair for water, sewage, waste and raw materials management. Besuchen Sie uns auf der IFAT 2014. Die Weltleitmesse für Wasser-, Abwasser-, Abfall- und Rohstoffwirtschaft 30 May to 03... Created on 01/04/2016 10:55 and updated on 10/04/2018 11:25 |
![]() News |
|
GAD 531 Level detection for grease-water separators Starting Up Notice (531-05)
Created on 31/05/2018 17:50 and updated on 28/04/2022 17:47 |
531-05![]() Starting Up Notice |
![]() |
EasyTREK Ultrasonic level transmitter Page (598-01)
• Height range 0.15 to 18 m, for liquids • Non-contact level measurement • HART® 7 protocole • Output signal 4-20 mA • IP 68 (allows accidental immersion) Created on 11/04/2019 11:02 and updated on 11/04/2019 11:09 |
598-01![]() Page |
![]() |
DKM/A Flow controller - Viscosity <600 Cst - 250/300 bar - 120 (160)°C - all positions - 0,5...90 l/min Page (723-02)
• Operates in all positions • Indicator, plus 1 adjustable contact • Versions: Stainless steel and brass • Pressure up to 300 bar • Viscosity: 30 ... 600 cSt • Flow ranges from 0.5 up to 90 l/min Created on 05/12/2019 15:33 and updated on 26/06/2023 17:55 |
723-02![]() Page |
![]() |
P103 Pressure gauge, stainless steel / EN 837-1 Page (812-54)
• Mechanical system in stainless steel • Case Ø 63 mm • Ranges from -1 ... up to 1000 bar Created on 11/06/2020 15:03 and updated on 11/06/2020 15:09 |
812-54![]() Page |
![]() |
VMP FE PVC manual butterfly valves Page (945-05)
• Secure and padlockable handle • Multiple adjustment positions • Wafer mounting, between flanges: DIN2501, ISO DIS 9624, UNI2223, BS10 table D/E, ASA B16.5 class 150 Created on 15/02/2021 17:23 and updated on 17/04/2026 11:46 |
945-05![]() Page |
![]() |
D103 Welded one-piece gauge guard Page (812-40)
Created on 07/02/2022 10:57 and updated on 07/02/2022 11:04 |
812-40![]() Page |
|
MAGTOP-D Level indicator - ATEX or/and P.E.D. Starting Up Notice (560-03)
Created on 14/03/2022 17:36 and updated on 14/03/2022 17:37 |
560-03![]() Starting Up Notice |
|
TYPE 620 Composite water-meter Starting Up Notice (786-20)
Created on 09/10/2023 12:27 and updated on 09/10/2023 12:29 |
786-20![]() Starting Up Notice |
![]() |
DF 11 Rotating paddle level switch Page (510-02)
For powders and granules Threaded fittings Extension: Up to 2000 mm ATEX options: Dust Created on 17/06/2025 13:14 and updated on 17/06/2025 13:19 |
510-02![]() Page |
![]() |
DB Series Orifice Plate, flow-meters Page (765-01)
• For agressive liquids • Direct reading indicator on pipes from ND 50 up to ND 200 • Mounting in all positions • According standard NF X 10-102 • Options: Flow contact; Output signal Created on 09/10/2006 16:55 and updated on 30/12/2020 09:27 |
765-01![]() Page |
![]() |
RTM Continuous level transmitter Page (586-01)
Signal output: 4-20 mA Step: 10 mm The RTM is adapted to our level indicators MAGTOP, SFA, MNR 6 and MNR 7. • Output signal: or 4-20 mA or resistor • Customized models • Direct mounting on top of a tank • Direct mounting on MAGTOP and SFA... Created on 27/03/2007 14:20 and updated on 12/02/2020 14:08 |
586-01![]() Page |
![]() |
TRUBOMAT GAB In line turbidity transmitter Starting Up Notice (446-01)
Created on 31/07/2007 14:20 and updated on 10/04/2018 09:41 |
446-01![]() Starting Up Notice |
![]() |
BAMOMATIC Electromagnetic Flowmeter Starting Up Notice (775-01)
Created on 14/10/2008 18:04 and updated on 10/04/2018 11:02 |
775-01![]() Starting Up Notice |
![]() |
BAMOMATIC An accurate and tiny little flow rate metre News (news bamomatic)
Since we launched the BAMOMATIC (in 2004), its success is increasing with more than a few thousands of units in use. They are still new applications to discover for this electromagnetic and small metre; the most well known are dosage and flow-rate... Created on 21/12/2009 16:12 and updated on 10/04/2018 11:37 |
news bamomatic![]() News |
![]() |
PES7 Peracetic acid sensor Page (193-30)
Disinfection process in food industry Ranges: 0...2000 ppm Unnecessary zero adjustment Only 1 point requested for calibration Created on 27/09/2010 16:58 and updated on 05/05/2025 10:41 |
193-30![]() Page |
![]() |
VORTEX Flow sensor, Vortex type Page (777-01)
• Flow-rate sensor for domestic hot water, drinkable water, demineralised water • Measuring range from 0.9 to 150 l/min • Pipes from ND 8 to ND 25 mm • Output signal: or 4-20 mA or pulses • Drinkable water approvals: WRAS,ACS Created on 19/01/2011 14:11 and updated on 04/04/2022 11:10 |